A nafion film cover to enhance the analytical performance of the CuO/Cu electrochemical sensor for determination of chemical oxygen demand

26Citations
Citations of this article
32Readers
Mendeley users who have this article in their library.

Abstract

We modified and evaluated the performance of a CuO/Cu electrochemical electrode for chemical oxygen demand (COD) determination by covering it with a Nafion (Nf) film. The resulting modified CuONf/Cu electrode sensor was used for the electrochemical determination of COD in river, slaughterhouse and estuarine water samples in order to evaluate its performance for this particular task. It was compared with the CuO/Cu sensor with no Nafion. The main electrochemical characteristics of interest, resistance, sensitivity, accuracy and reproducibility, were assessed by means of Linear Sweep Voltammetry using glucose as a standard. Results of these essays indicate that the procedure used produced smooth and firmly attached Nf films covering the whole copper surface. This sensor was shown to be resistant to interferences and effective in electro-oxidation of a wide range of organic compounds and therefore very useful for COD determination. Using the newly developed CuONf/Cu electrode an analytical linear range of 50 to 1000 mg·L −1 COD, with a detection limit of 2.11 mg·L −1 (n = 6) COD was achieved. The comparison shows that the CuONf/Cu sensor is more appropriate for COD determination than its counterpart with no Nafion.

References Powered by Scopus

Application of Polymer-Coated Glassy Carbon Electrodes in Anodic Stripping Voltammetry

225Citations
N/AReaders
Get full text

Electrocatalysis and Amperometric Detection Using an Electrode Made of Copper Oxide and Carbon Paste

223Citations
N/AReaders
Get full text

Comparison of metallic electrodes for constant-potential amperometric detection of carbohydrates, amino acids and related compounds in flow systems

183Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Portable Photoelectrochromic Visualization Sensor for Detection of Chemical Oxygen Demand

46Citations
N/AReaders
Get full text

Rapid Potentiometric Detection of Chemical Oxygen Demand Using a Portable Self-Powered Sensor Chip

26Citations
N/AReaders
Get full text

Compact fluidic electrochemical sensor platform for on-line monitoring of chemical oxygen demand in urban wastewater

25Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Carchi, T., Lapo, B., Alvarado, J., Montero, P. J. E., Llorca, J., & Fernández, L. (2019). A nafion film cover to enhance the analytical performance of the CuO/Cu electrochemical sensor for determination of chemical oxygen demand. Sensors (Switzerland), 19(3). https://doi.org/10.3390/s19030669

Readers' Seniority

Tooltip

Researcher 5

45%

PhD / Post grad / Masters / Doc 4

36%

Professor / Associate Prof. 2

18%

Readers' Discipline

Tooltip

Chemistry 9

64%

Chemical Engineering 3

21%

Materials Science 1

7%

Computer Science 1

7%

Article Metrics

Tooltip
Mentions
Blog Mentions: 1
Social Media
Shares, Likes & Comments: 19

Save time finding and organizing research with Mendeley

Sign up for free