Segurança e eficácia dos stents farmacológicos eluidores de biolimus com polímero biodegradável: análise do registro EINSTEIN (Evaluation of Next-generation drug-eluting STEnt IN patients with coronary artery disease)

  • Souza C
  • El Mouallem A
  • Brito Júnior F
  • et al.
N/ACitations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

OBJETIVO: Avaliar a incidência de eventos adversos cardíacos maiores (morte cardíaca, infarto agudo do miocárdio ou necessidade de nova revascularização do vaso-alvo) em 1 ano em pacientes do "mundo real". MÉTODOS: O registro EINSTEIN é um estudo observacional prospectivo, unicêntrico, que incluiu consecutivamente 103 pacientes (152 lesões) tratados com o stent BiomatrixTM, eluidor de biolimus A9 e polímero biodegradável. RESULTADOS: A média das idades foi de 65,0±12,4 anos; o gênero masculino representou 83,5% dos pacientes; e 37,9% deles eram diabéticos. Em 1 ano, eventos adversos cardíacos maiores ocorreram em 11,7% dos pacientes, incluindo 2,9% de morte cardíaca, 4,9% de infarto agudo do miocárdio sem supradesnivelamento do segmento ST e 3,9% de revascularização do vaso-alvo. Trombose de stent esteve presente em apenas 1% (1 paciente) após o seguimento clínico de 1 ano. CONCLUSÃO: O presente registro sugere que os novos stents farmacológicos eluidores de biolimus A9 com polímero biodegradável são seguros e eficazes em pacientes da prática clínica diária, com baixas taxas de eventos adversos cardíacos maiores no longo prazo.OBJECTIVE: To evaluate the incidence of major adverse cardiac events (cardiac death, or acute myocardial infarct, or target vessel revascularization) at one year in "real world" patients. METHODS: The EINSTEIN registry is an observational, prospective, single center study that consecutively included 103 patients (152 lesions) treated with the BiomatrixTM stent, a biolimus A9-eluting stent with biodegradable polymer. RESULTS: The mean age was 65.0±12.4 years; male gender represented 83.5% of the patients; and 37.9% of them were diabetic. At one-year, major adverse cardiac events occurred in 11.7% of the patients, including 2.9% of cardiac death, 4.9% of with non ST- segment elevation acute myocardial infarction, and 3.9% of target vessel revascularization. Stent thrombosis occurred in only 1% (1 patient) at one-yearfollow-up. CONCLUSION: The present Registry suggests that new generation biolimus A9 drug-eluting stents are safe and effective in a "real world", all-comers patients, showing low rates of major cardiac adverse events on long-term follow-up.

Cite

CITATION STYLE

APA

Souza, C. F. de, El Mouallem, A. M., Brito Júnior, F. S. de, Abizaid, A. A. C., Almeida, B. O., Almeida, A. G., … Caixeta, A. (2013). Segurança e eficácia dos stents farmacológicos eluidores de biolimus com polímero biodegradável: análise do registro EINSTEIN (Evaluation of Next-generation drug-eluting STEnt IN patients with coronary artery disease). Einstein (São Paulo), 11(3), 350–356. https://doi.org/10.1590/s1679-45082013000300015

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free