Evaluation of X-ray radiation shielding performance of Bi2O3 and BaTiO3 embedded in PVP and PEG polymer nanocomposite

5Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.
Get full text

Abstract

This study addressed the limitations of lead-based radiation shields by developing lead-free, non-toxic, lightweight, and flexible shielding materials with high attenuation efficiency. To achieve this, single and triple layers of Bi2O3-BaTiO3/PVP-PEG nanocomposite films were synthesized. Polyvinylpyrrolidone (PVP) and polyethylene glycol (PEG) polymers (2:1 ratio) were used as the polymeric matrix in which fillers of Bi2O3 and BaTiO3 nanoparticles (NPs) with particle sizes ranging from 90 to 210 nm and <100 nm, respectively, were embedded. Four single-layer samples with 20%, 30%, 40%, and 50% NP concentrations were prepared; the samples were 1.05, 1.09, 1.27, and 1.42 mm thick, respectively. Two samples of triple-layered films were prepared with 30% and 50% NPs, measuring 3.78 and 4.23 mm in thickness, respectively. The attenuation efficiency of these films was investigated using X-ray tube voltages from 10 to 120 kVp. Further, the flexibility of the synthesized films was tested by manual handling. All single- and triple-layer nanocomposites exhibited effective radiation attenuation and desirable flexibility. Specifically, at the lowest tube voltage, all samples exhibited 100% attenuation, while at the highest tube voltage, the attenuation ranged from 27% to 84%, depending on the NP concentration and number of layers of the sample. The highest attenuation ratio, observed in the 50% triple-layer sample, reached 100% up to approximately 60 kVp and 84% at 120 kVp. Consequently, the most optimal film synthesized in this study had a triple-layer configuration with 50% Bi2O3-BaTiO3 NPs embedded in a PVP-PEG polymer with an average attenuation of 95.5% for all tube voltages (10–120 kVp). Therefore, this shielding is suitable for various diagnostic applications, such as mammography, dental X-rays, computerized tomography, and fluoroscopy. Highlights Single- and triple-layered nanocomposite Bi2O3-BaTiO3/PVP-PEG films were synthesized The attenuation efficiency of the films against X-rays was investigated A triple-layer configuration with 50% Bi2O3-BaTiO3/PVP-PEG was suitable for various diagnostic applications.

Cite

CITATION STYLE

APA

Bawazeer, O., Baatiyah, B., Al Amoudi, S., Aga, Z., Matar, Z., Khan, S., … Ajlouni, A. (2025). Evaluation of X-ray radiation shielding performance of Bi2O3 and BaTiO3 embedded in PVP and PEG polymer nanocomposite. Radiation Effects and Defects in Solids, 180(3–4), 463–475. https://doi.org/10.1080/10420150.2024.2381232

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free