We demonstrate the design and fabrication of an in-line evanescent field gas sensor based on a novel suspended ring-core photonic crystal fiber (PCF) to further overcome limitations in sensing capability. The suspended ring-core PCF is made by the stack-and-draw technique with a large central capillary of ∼60 μm and adapted small capillaries in a larger cladding tube. Sensing capabilities of two variations of the proposed suspended ring-core PCFs were investigated experimentally by detecting absorption lines of acetylene gas. The sensitivity of the two PCF structures was also numerically analyzed using a full-vectorial finite-element method. The dynamic response of the sensors was quantified in detail. The results demonstrated significant improvement in both sensitivity and response time of the suspended ring-core PCF as this special PCF can provide larger gas diffusion and higher overlap between the sensing species and the guided light than either a Ge-doped ring defect PCF or a conventional index-guided PCF.
CITATION STYLE
Kassani, S. H., Khazaeinezhad, R., Jung, Y., Kobelke, J., & Oh, K. (2015). Suspended ring-core photonic crystal fiber gas sensor with high sensitivity and fast response. IEEE Photonics Journal, 7(1). https://doi.org/10.1109/JPHOT.2015.2396121