Abstract

A prefabricated monolithic slab (PMS) has a number of valuable advantages, they allow to significantly decrease the weight of construction keeping the necessary structural-load capacity, to speed up and cheapen work conduction, to increase the heat isolating properties of an enclosure structure [1]. In order to create a design method of prefabricated monolithic slab fire-resistance, it's necessary to perform a series of PMS testing, one of which is being described in this article. Subjected to the test is a fragment of prefabricated monolithic slab with polystyrene concrete inserts along the beams with bent metal profile 250 mm thick, with a 2.7 m span loaded with evenly spread load equal to 600 kg/m2. After 3 hour testing for fire-resistance [2] no signs of construction ultimate behavior were detected.

Cite

CITATION STYLE

APA

Gravit, M., Nedviga, E., Vinogradova, N., & Teplova, Z. (2017). Fire resistance of prefabricated monolithic slab. In MATEC Web of Conferences (Vol. 106). EDP Sciences. https://doi.org/10.1051/matecconf/201710602025