Pressure Loss and Liquid Holdup in Packed Bed Reactor With Cocurrent Gas-Liquid Down Flow

89Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

Abstract

Paying attention to the discrepancy between available data, probably due to the uncertainty in void fraction, the entrance end effect and characteristics of the experimental method, new experimental results were obtained for air-water flow in 65.8 and 122 mm I.D. columns packed with glass spheres of six different sizes between 2.59 and 24.3 mmf The two-phase pressure loss based on an energy (not momentum) balance was correlated in terms of Lockhart-Martinelli parameters as follows: ^ = 1.30+1.85% o.85, 0.1

Cite

CITATION STYLE

APA

Toda, M., Takahashi, F., & Hirose, T. (1973). Pressure Loss and Liquid Holdup in Packed Bed Reactor With Cocurrent Gas-Liquid Down Flow. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 6(2), 147–152. https://doi.org/10.1252/jcej.6.147