Abstract
Pre-breakdown voltage is a phenomenon of dielectric breakdown affecting insulation’s performance. The faster pre-breakdown voltage of insulation, the more significant its dielectric degradation. In this paper, pre-breakdown voltage in oil insulation was investigated by using DC high voltage in laboratory scale. Under testing, the streamer development was recorded by using a high-resolution camera. The measured current was synchronized with an image that was picked up during the oil insulation testing. By this experiment, the characteristics of the current in phenomenon pre-breakdown voltage at oil insulation was studied. The results showed that the measured current of pre-breakdown phenomenon in oil insulation under 28 kV to 30 kV excitation voltage is in a range 100 mA - 150 mA.
Cite
CITATION STYLE
Negara, I. M. Y., Fahmi, D., Asfani, D. A., & Cahyaningrum, D. K. (2018). Analisis Karakteristik Fenomena Pre-Breakdown Voltage Berbasis Pengujian pada Media Isolasi Minyak. Majalah Ilmiah Teknologi Elektro, 16(3), 128. https://doi.org/10.24843/mite.2017.v16i03p20