Validation of a Web-Based Planning Tool for Percutaneous Cryoablation of Renal Tumors

6Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

Abstract

Purpose: To validate a simulation environment for virtual planning of percutaneous cryoablation of renal tumors. Materials and Methods: Prospectively collected data from 19 MR-guided procedures were used for validation of the simulation model. Volumetric overlap of the simulated ablation zone volume (Σ) and the segmented ablation zone volume (S; assessed on 1-month follow-up scan) was quantified. Validation metrics were DICE Similarity Coefficient (DSC; the ratio between twice the overlapping volume of both ablation zones divided by the sum of both ablation zone volumes), target overlap (the ratio between the overlapping volume of both ablation zones to the volume of S; low ratio means S is underestimated), and positive predictive value (the ratio between the overlapping volume of both ablation zones to the volume of Σ; low ratio means S is overestimated). Values were between 0 (no alignment) and 1 (perfect alignment), a value > 0.7 is considered good. Results: Mean volumes of S and Σ were 14.8 cm3 (± 9.9) and 26.7 cm3 (± 15.0), respectively. Mean DSC value was 0.63 (± 0.2), and ≥ 0.7 in 9 cases (47%). Mean target overlap and positive predictive value were 0.88 (± 0.11) and 0.53 (± 0.24), respectively. In 17 cases (89%), target overlap was ≥ 0.7; positive predictive value was ≥ 0.7 in 4 cases (21%) and < 0.6 in 13 cases (68%). This indicates S is overestimated in the majority of cases. Conclusion: The validation results showed a tendency of the simulation model to overestimate the ablation effect. Model adjustments are necessary to make it suitable for clinical use.

References Powered by Scopus

Analysis of tissue and arterial blood temperatures in the resting human forearm

4949Citations
N/AReaders
Get full text

Morphometric Analysis of White Matter Lesions in MR Images: Method and Validation

1139Citations
N/AReaders
Get full text

European Association of Urology Guidelines on Renal Cell Carcinoma: The 2019 Update

1050Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Hybrid simulation and planning platform for cryosurgery with microsoft hololens

22Citations
N/AReaders
Get full text

Microwave ablation of lung tumors: A probabilistic approach for simulation-based treatment planning

18Citations
N/AReaders
Get full text

Intraoperative MRI-derived volumetric ablation margins and initial correlation with local outcome after MRI-guided cryoablation of renal tumors

5Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

van Oostenbrugge, T. J., Heidkamp, J., Moche, M., Weir, P., Mariappan, P., Flanigan, R., … Fütterer, J. J. (2020). Validation of a Web-Based Planning Tool for Percutaneous Cryoablation of Renal Tumors. CardioVascular and Interventional Radiology, 43(11), 1661–1670. https://doi.org/10.1007/s00270-020-02634-y

Readers' Seniority

Tooltip

Researcher 4

67%

PhD / Post grad / Masters / Doc 2

33%

Readers' Discipline

Tooltip

Medicine and Dentistry 5

71%

Social Sciences 1

14%

Engineering 1

14%

Save time finding and organizing research with Mendeley

Sign up for free