Influence of respiratory mechanics and drive on genioglossus movement under ultrasound imaging

7Citations
Citations of this article
53Readers
Mendeley users who have this article in their library.

Abstract

Genioglossus is the largest upper airway dilator and its dilatory movement can be measured non-invasively with magnetic resonance imaging and ultrasound. The present study used a novel ultrasound method to assess genioglossus movement in conditions in which ventilatory drive or respiratory mechanics were changed. Methods Twenty healthy subjects (10 males, age 28±5 years [mean ± SD]) lay supine, awake, with the head in a neutral position. Ventilation was monitored with inductance bands. Real-time B-mode ultrasound movies were analysed. We measured genioglossus motion (i) during spontaneous breathing, voluntary targeted breathing (normal tidal volume Vt), and voluntary hyperpnoea (at 1.5Vt and 2 Vt); (ii) during inspiratory flow resistive loading; (iii) with changes in end-expiratory lung volume (EELV). Results Average peak inspiratory displacement of the infero-posterior region of genioglossus was 0.89±0.56 mm; 1.02±0.88 mm; 1.27±0.70 mm respectively for voluntary Vt, and during voluntary hyperpnoea at 1.5Vt and 2Vt. A change in genioglossus motion was observed with increased Vt. During increasing inspiratory resistive loading, the genioglossus displaced less anteriorly (p = 0.005) but more inferiorly (p = 0.027). When lung volume was altered, no significant changes in genioglossus movement were observed (p = 0.115). Conclusion In healthy subjects, we observed non-uniform heterogeneous inspiratory motion within the inferoposterior part of genioglossus during spontaneous quiet breathing with mean peak displacement between 0.5–2 mm, with more displacement in the posterior region than the anterior. This regional heterogeneity disappeared during voluntary targeted breathing. This may be due to different neural drive to genioglossus during voluntary breathing. During inspiratory resistive loading, the observed genioglossus motion may serve to maintain upper airway patency by balancing intraluminal negative pressure with positive pressure generated by upper airway dilatory muscles. In contrast, changes in EELV were not accompanied by major changes in genioglossus motion.

Cite

CITATION STYLE

APA

Kwan, B. C. H., McBain, R. A., Luu, B. L., Butler, J. E., Bilston, L. E., & Gandevia, S. C. (2018). Influence of respiratory mechanics and drive on genioglossus movement under ultrasound imaging. PLoS ONE, 13(4). https://doi.org/10.1371/journal.pone.0195884

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free