Influence of control valve delay and dead zone on the stability of a simple hydraulic positioning system

13Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

Abstract

This paper deals with the PI control of a highly simplified dynamic model of a hydraulic cylinder. It is assumed that the hydraulic fluid is incompressible and that the pump provides constant flow rates, which results in the possibility of velocity control. Two types of anomalies are taken into account: (a) the time delay due to the controller computations and the internal pressure dynamics and (b) the dead zone of the controller valve. This results in a nonlinear system are described by a piecewise linear discontinuous map. Nonlinear behavior of the system is explored and the practically globally stable parameter domains are identified. Copyright 2010 Blint Magyar et al.

Cite

CITATION STYLE

APA

Magyar, B., Hós, C., & Stépán, G. (2010). Influence of control valve delay and dead zone on the stability of a simple hydraulic positioning system. Mathematical Problems in Engineering, 2010. https://doi.org/10.1155/2010/349489