Improved constant on-time controlled buck converter with high output-regulation accuracy

6Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

Constant on-time (COT) control has been widely applied in industrial applications due to its fast transient response. However, the conventional COT controlled buck converter has poor output-regulation accuracy. A new control method, called improved COT (ICOT) control, that provides both high output-regulation accuracy and fast transient response for the buck converter is proposed. Circuit simulation results validate the correctness of the theoretical analysis.

Cite

CITATION STYLE

APA

Chen, X., Zhou, G., Zhang, K., & Zhou, S. (2015). Improved constant on-time controlled buck converter with high output-regulation accuracy. Electronics Letters, 51(4), 359–360. https://doi.org/10.1049/el.2014.4261