Comparison of 1.8-mm incision versus 2.75-mm incision cataract surgery in combined phacoemulsification and 23-gauge vitrectomy

15Citations
Citations of this article
39Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To compare 1.8 mm micro-incision and 2.75 mm standard incision in coaxial cataract surgery combined with 23-Gauge (23G) vitrectomy with respect to intraoperative and postoperative complications and outcomes. Methods: In this prospective study 30 eyes of 30 patients planned for combined phacoemulsification and 23G vitrectomy were enrolled, and randomized to undergo either Standard 2.75 mm Incision Cataract Surgery (SICS, 15 eyes) or Coaxial 1.8 mm Micro-Incision Cataract Surgery (C-MICS, 15 eyes) followed by vitrectomy. Inclusion criteria were cataract and macular disorders including macular hole, epiretinal membrane and vitreomacular traction. Data were collected at preoperative evaluation and 1 and 12 months or more after surgery. Results: Incision leakage occurred in two eyes (7%: one per group), retinal break in nine (30%: four in C-MICS, five in SICS). Fibrin in anterior chamber (AC) occurred day 1 in three eyes (10%: two C- and one SICS). Posterior capsule opacification developed in 22 eyes (78%: 13 MICS, nine SICS, p = 0.1). A myopic shift of −0.63 ± 0.7 was noted (−0.59 ± 0.8 MICS, −0.68 ± 0.6 SICS, p = 0.74). Surgically induced astigmatism (SIA) was significantly smaller in C-MICS group (ΔKP, −0.019 ± 0.095 versus −0.141 ± 0.219, p = 0.0038) at 1 month but not at final follow-up (ΔKP, 0.0005 ± 0.16 in C-MICS versus −0.057 ± 0.12, p = 0.3. Conclusions: Both techniques were equally safe with respect to intraoperative and postoperative findings. Coaxial micro-incision cataract surgery (C-MICS) was associated with less surgically-induced astigmatism (SIA) 1 month after surgery but differences were not statistically significant at final follow-up indicating a faster refractive recovery with C-MICS than with SICS.

Cite

CITATION STYLE

APA

Czajka, M. P., Frajdenberg, A., & Johansson, B. (2016). Comparison of 1.8-mm incision versus 2.75-mm incision cataract surgery in combined phacoemulsification and 23-gauge vitrectomy. Acta Ophthalmologica, 94(5), 507–513. https://doi.org/10.1111/aos.12998

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free