Accuracy of the ankle-brachial index using the SCVL®, an arm and ankle automated device with synchronized cuffs, in a population with increased cardiovascular risk

14Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.

Abstract

Objective: To evaluate the accuracy of the ankle brachial index (ABI) measured with the SCVL® ("screening cardiovascular lab"; GenNov, Paris, France), an automated device with synchronized arm and ankle cuffs with an automatic ABI calculation. Methods: Patients were consecutively included in a cardiovascular prevention unit if they presented with at least two cardiovascular risk factors. ABI measurements were made using the SCVL, following a synchronized assessment of brachial and ankle systolic pressure. These values were compared to the ABI obtained with the usual Doppler-assisted method. Results: We included 157 patients. Mean age was 59.1 years, 56.8% had hypertension, 22.3% had diabetes mellitus, and 17.6% were current smokers. An abnormal ABI was observed in 17.2% with the SCVL and in 16.2% with the Doppler. The prevalence rates of an abnormal ABI by patient measured with each device, ie, 15.7% (confidence interval [CI] 0.95: [11.8; 20.4]) or 14.3% (CI 0.95: [10.7; 18.9]), did not differ. The coefficient of variation of Doppler and SCVL measures was 15.8% and 15.1%, respectively. The regression line between the two measurement methods was statistically significant. The value-to-value comparison also shows a difference of mean equal to 0.010 (CI 0.95: [-0.272; 0.291]) (r = -0.055). Reproducibility of ABI measurements with the SCVL showed a difference of mean equal to 0.009 (CI 0.95: [-0.203; 0.222]), without heteroscedasticity (r = -2212;0.003). Conclusion: The SCVL is a fast and easy to use automated oscillometric device for the determination of ABI. The use of this two-synchronized-cuff device correlates well with the gold standard Doppler ultrasound method and is reproducible. The SCVL may ease the screening for peripheral arterial disease in routine medical practice. © 2012 Rosenbaum et al, publisher and licensee Dove Medical Press Ltd.

Cite

CITATION STYLE

APA

Rosenbaum, D., Rodriguez-Carranza, S., Laroche, P., Bruckert, E., Giral, P., & Girerd, X. (2012). Accuracy of the ankle-brachial index using the SCVL®, an arm and ankle automated device with synchronized cuffs, in a population with increased cardiovascular risk. Vascular Health and Risk Management, 8(1), 239–246. https://doi.org/10.2147/VHRM.S29405

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free