Absolute Hugoniot measurements for empty plastic foams at ∼10% of solid polystyrene density and supporting rad-hydro simulation results are reported. Planar foam slabs, ∼400 μm thick and ∼500 μm wide, some of which were covered with a 10 μm solid plastic ablator, were directly driven by 4 ns long Nike krypton-fluoride 248 nm wavelength laser pulses that produced strong shock waves in the foam. The shock and mass velocities in our experiments were up to 104 km/s and 84 km/s, respectively, and the shock pressures up to ∼9 Mbar. The motion of the shock and ablation fronts was recorded using side-on monochromatic x-ray imaging radiography. The steadiness of the observed shock and ablation fronts within ∼1% has been verified. The Hugoniot data inferred from our velocity measurements agree with the predictions of the SESAME and CALEOS equation-of-state models near the highest pressure ∼9 Mbar and density compression ratio ∼5. In the lower pressure range 2-5 Mbar, a lower shock density compression is observed than that predicted by the models. Possible causes for this discrepancy are discussed.
CITATION STYLE
Aglitskiy, Y., Velikovich, A. L., Karasik, M., Schmitt, A. J., Serlin, V., Weaver, J. L., … Cochrane, K. R. (2018). Absolute Hugoniot measurements for CH foams in the 2-9 Mbar range. Physics of Plasmas, 25(3). https://doi.org/10.1063/1.5020422