Cytotoxicity and antibody binding by flow cytometry: A single assay to simultaneously assess two parameters

21Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Cell death, as determined by complement-dependent cytotoxicity or antibody binding, as assessed by flow cytometry, are the two main methods histocompatibility laboratories use to identify HLA antibodies. Conventional cytotoxicity assays, even anti-human globulin (AHG) enhanced, are relatively insensitive, subjective and require complement fixation. In contrast, antibody binding assays (e.g.: flow cytometry crossmatch, FCXM) are sensitive, objective, and complement independent. When sera from potential transplant recipients test positive by both methods, most centers would not proceed to transplant unless patients undergo desensitization. However, when the CDC crossmatch is negative but the FCXM positive, how or whether to proceed is controversial. Frequently, both assays are performed. Methods: In this study, we developed a comprehensive procedure that determines cell death, and antibody binding in a single assay: the cytotoxic flow crossmatch (cFCXM). The assay was validated in parallel studies with two other conventional methodologies, namely AHG and FCXM. Results: Using a combination of eight cells and 15 sera, we have determined an optimal method for the simultaneous detection of HLA antibody binding and cytotoxicity using a single platform. Additionally, we have identified three distinct patterns of HLA antibody reactivity: (1) AHGpos/cFCXMpos/FCXMpos, (2) AHGneg/cFCXMneg/ FCXMpos, and (3) a previously unrecognized category, namely, AHGneg/cFCXMpos/FCXMpos. Conclusions: These studies document that cytotoxicity and antibody binding can be simultaneously assessed and marks the first demonstration of complement-dependent HLA antibodies undetectable by conventional cytotoxicity. Routine application of this assay may provide new insights regarding transplantation of patients presenting as AHGneg/FCXMpos by classifying them according to their cFCXM status. © 2008 Clinical Cytometry Society.

Cite

CITATION STYLE

APA

Saw, C. L., Bray, R. A., & Gebel, H. M. (2008). Cytotoxicity and antibody binding by flow cytometry: A single assay to simultaneously assess two parameters. Cytometry Part B - Clinical Cytometry, 74(5), 287–294. https://doi.org/10.1002/cyto.b.20424

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free