An innovative smart concrete anchorage with self-stress sensing capacity of prestressing stress of PS tendon

4Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

An innovative smart concrete anchorage (SCA) has been developed for monitoring the stress of prestressing (PS) tendons by utilizing smart ultra-high-performance concrete (UHPC). The smart UHPC contained 2 vol% steel fibers and fine steel slag aggregates instead of silica sands. The effects of different electrode materials, arrangements, and connectors on the self-stress sensing capacity of the SCA are discussed. A prototype SCA demonstrated its feasibility and sufficient self-stress sensing capacity to be used in monitoring the prestressing loss of the PS tendon. As the tensile stress of the PS tendon increased from 0 to 1488 MPa, the fractional change in resistivity (FCR) of the prototype SCA, with horizontally paired copper wire electrodes and a plug-in type connector, decreased linearly from 0% to −1.53%, whereas the FCR increased linearly from −1.53% to −0.04% as the tensile stress of the PS tendon decreased from 1488 to 331 MPa.

Cite

CITATION STYLE

APA

Lee, S. Y., Le, H. V., Kim, M. K., Kim, D. J., & Park, J. (2021). An innovative smart concrete anchorage with self-stress sensing capacity of prestressing stress of PS tendon. Sensors, 21(15). https://doi.org/10.3390/s21155251