A comparative study of haemodynamic effects of single-blinded orotracheal intubations with intubating laryngeal mask airway, Macintosh and McGrath video laryngoscopes

5Citations
Citations of this article
42Readers
Mendeley users who have this article in their library.

Abstract

Background: The efficacy of an intubation technique is crucial to the success of ventilation therapies. Intubating laryngeal mask airway (ILMA), Macintosh and McGrath techniques are yet to be evaluated thoroughly. Orotracheal intubations with ILMA, McGrath, and Macintosh laryngoscopes are compared based on haemodynamic changes, time taken for intubations, and success rate. Methods: This is a prospective, single-blinded, randomised controlled trial. Primary outcome: identification of the most efficient intubation technique. Secondary outcomes: haemodynamic parameters, time taken for intubation and the rate of success of intubation. Patients enrolled: 90. Groups: 3. Each participant is randomly assigned to a group. Inclusion criteria: both sexes, age: 18–55 years, ASA: I or II, Mallampati < III, Mouth opening > 2 fingers, BMI < 40 kg m-2, any elective surgery, general anaesthesia requiring endotracheal intubation. The haemodynamic changes, time taken for intubations, and success rate during ILMA, Macintosh and McGrath intubations were recorded and statistically analysed. Results: Macintosh and ILMA raised the heart rate (min-1) more than McGrath at the second minute (95% CI: 76.50 ± 1.34 [McGrath] < 81.73 ± 1.46 [Macintosh] < 90.42 ± 1.24 [ILMA]). ILMA required the longest intubation time (s) (95% CI: 71.64 ± 2.14 [ILMA] > 40.26 ± 1.36 [McGrath] > 30.63 ± 1.53 [Macintosh]). Macintosh and McGrath intubations were all successful, whereas ILMA recorded two failures. However, the observed failures were statistically insignificant (95% CI: 93.33 ± 4.35%). Conclusions: McGrath intubation is the most efficient technique based on its haemodynamics. ILMA required the longest intubation time and statistically, rates of success of the techniques are alike.

Cite

CITATION STYLE

APA

Anandraja, R., & Ranjith Karthekeyan, B. (2021). A comparative study of haemodynamic effects of single-blinded orotracheal intubations with intubating laryngeal mask airway, Macintosh and McGrath video laryngoscopes. Anaesthesiology Intensive Therapy, 53(1), 30–36. https://doi.org/10.5114/ait.2021.103663

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free