Nion UltraSTEM: An Aberration-Corrected STEM for Imaging and Analysis

  • Bacon N
  • Corbin G
  • Dellby N
  • et al.
N/ACitations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Adding a Nion spherical aberration (C s) corrector [1] to a Vacuum Generators (VG) scanning transmission electron microscope (STEM) typically improves its resolution by 2-2.5x, i.e. to better than 1 Å at 100 keV [2] and to about 0.6 Å at 300 kV [3]. This has resulted in many new applications for these instruments, such as numerous determinations of new structures, dynamic studies, and single-atom-sensitivity EELS (e.g. [4]). VG STEMs have several attributes that make such performance possible when retrofitted with an aberration corrector. The chief one is the high quality of their cold field emission guns (CFEGs), whose brightness is typically >10 9 A/(cm 2 sr) at 100 kV. However, they also have weaknesses that create barriers to further progress. The VG condensers are difficult to align and drift for more than an hour if their current is changed. The objective lens in the 100 kV VG has a large upper bore, which prevents it from operating as a Riecke-type symmetric condenser-objective lens with minimized aberration parameters on both the entry and exit sides of the lens. Further, most 100 kV VGs have no sample height (Z) adjustment capability, and have a weak post-sample objective lens field. This saddles them with varying optical parameters when the sample tilt is changed, and with poor post-sample compression and consequently a hard-to-optimize EELS collection efficiency. Addressing these problems is essential for further progress, and this is the path now pursued at Nion. Accordingly, we are developing a new STEM column, and also a new 200 kV cold field emission electron gun. The two projects presently proceed on separate tracks. New columns #1 and #2 are being assembled on top of existing 100 kV VG guns. They will be delivered in this configuration, with projected properties superior to any 100 kV VG. The new gun is being developed in a separate lab. In the long run, the new column and the new CFEG will be combined in an instrument named Nion UltraSTEM™. The new column incorporates a new aberration corrector of fifth order aberration (C 5) in addition to C s , described elsewhere in these proceedings [5]. It further has three condenser lenses (two round lenses plus a lens made from 3 quadrupoles) a symmetrical condenser-objective lens with C s ~C c ~0.8 mm, an ultra-stable 5-axis goniometer based on new construction principles, a detachable side-entry specimen cartridge that gives +/-30° of tilt in all directions, two post-specimen round lenses, a quadrupole lens module for EELS coupling, and a variety of detectors including bright-field, high-angle and medium-angle dark-field detectors, a 1k x 1k CCD camera for Ronchigram and general diffraction pattern recording, and a parallel detection EELS (Gatan Enfina). Theoretical HAADF resolution at 200 kV is better than 0.4 Å [5]. Table 1 compares the key properties of the new STEM with the VG STEM and a typical modern TEM/STEM column. Fig. 1 shows a mechanical drawing of the entire UltraSTEM™ including the new CFEG. Fig. 2 shows the new column being tested at Nion. In summary, a new dedicated STEM with a 200 kV CFEG, a C3/C5 aberration corrector, and several other new design elements is being developed at Nion. Results from its new electron-optical column will be presented at the meeting. [1] N.

Cite

CITATION STYLE

APA

Bacon, N. J., Corbin, G. J., Dellby, N., Hrncirik, P., Krivanek, O. L., McManama-Smith, A., … Szilagyi, Z. S. (2005). Nion UltraSTEM: An Aberration-Corrected STEM for Imaging and Analysis. Microscopy and Microanalysis, 11(S02). https://doi.org/10.1017/s1431927605509802

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free