Magnetic shield for turbomolecular pump of the Magnetized Plasma Linear Experimental device at Saha Institute of Nuclear Physics

6Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The turbo molecular pump of the Magnetized Plasma Linear Experimental device is protected from damage by a magnetic shield. As the pump runs continuously in a magnetic field environment during a plasma physics experiment, it may get damaged owing to eddy current effect. For design and testing of the shield, first we simulate in details various aspects of magnetic shield layouts using a readily available field design code. The performance of the shield made from two half cylinders of soft iron material, is experimentally observed to agree very well with the simulation results. © 2011 American Institute of Physics.

Cite

CITATION STYLE

APA

Biswas, S., Chattopadhyay, M., & Pal, R. (2011). Magnetic shield for turbomolecular pump of the Magnetized Plasma Linear Experimental device at Saha Institute of Nuclear Physics. Review of Scientific Instruments, 82(1). https://doi.org/10.1063/1.3522697