Bioimpedance spectroscopy (BIS) is routinely used in peritoneal dialysis patients and might aid fluid status assessment in patients with liver cirrhosis, but the effect of ascites volume removal on BIS-readings is unknown. Here we determined changes in BIS-derived parameters and clinical signs of fluid overload from before to after abdominal paracentesis. Per our pre-specified sample size calculation, we studied 31 cirrhotic patients, analyzing demographics, labs and clinical parameters along with BIS results. Mean volume of the abdominal paracentesis was 7.8 ± 2.6 L. From pre-to post-paracentesis, extracellular volume (ECV) decreased (20.2 ± 5.2 L to 19.0 ± 4.8 L), total body volume decreased (39.8 ± 9.8 L to 37.8 ± 8.5 L) and adipose tissue mass decreased (38.4 ± 16.0 kg to 29.9 ± 12.9 kg; all p < 0.002). Correlation of BIS-derived parameters from pre to post-paracentesis ranged from R² = 0.26 for body cell mass to R² = 0.99 for ECV. Edema did not correlate with BIS-derived fluid overload (FO ≥ 15% ECV), which occurred in 16 patients (51.6%). In conclusion, BIS-derived information on fluid status did not coincide with clinical judgement. The changes in adipose tissue mass support the BIS-model assumption that fluid in the peritoneal cavity is not detectable, suggesting that ascites (or peritoneal dialysis fluid) mass should be subtracted from adipose tissue if BIS is used in patients with a full peritoneal cavity.
CITATION STYLE
Schwaiger, E., Simon, A., Wabel, P., Schairer, B., Berner, C., Signorini, L., … Hecking, M. (2020). Bioimpedance spectroscopy for fluid status assessment in patients with decompensated liver cirrhosis: Implications for peritoneal dialysis. Scientific Reports, 10(1). https://doi.org/10.1038/s41598-020-59817-3
Mendeley helps you to discover research relevant for your work.