A New Double Probe System for Studies of Non-Uniform Plasmas

4Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

Abstract

A theoretical and experimental study was developed about the applicability of a double probe system consisting of two directional Langmuir probes, both probes being located separately in a plasma column. The current-voltage characteristic of the double probe was obtained considering a plasma with a drifting maxwellian electron velocity distribution function and stationary ion background. In deriving the characteristic of the double probe, the plasma parameters, namely, electron temperature (Te), electron density (Ne), electron drift velocity (Vde) and plasma potential (Vp) are assumed to be non-uniform. The double probe characteristic is also dependent on the angle between the axial direction of the electron drift and the normal to the collecting area of the probe. Each probe can be rotated such that this angle can be varied between zero and 180 degrees. Various probe characteristics were simulated using plasma parameters obtained by independent single probe measurements in the positive column of a low-pressure arc discharge in mercury vapor. Typical parameters of the positive column, used in the simulation, are: Te = 5 eV, Ne = 1017 m-3, vde = 8x105 ms -1. Experimental characteristics of the double probe were obtained and compared with the simulated results, showing good agreement. It is concluded that this directional probe system can be a reliable diagnostic tool especially for studies of non-uniform plasmas.

Cite

CITATION STYLE

APA

Petraconi, G., & Maciel, H. S. (2003). A New Double Probe System for Studies of Non-Uniform Plasmas. Brazilian Journal of Physics, 33(4 SPEC. ISS.), 782–787. https://doi.org/10.1590/s0103-97332003000400030

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free