Efficacy and safety of flash glucose monitoring in patients with type 1 and type 2 diabetes: a systematic review and meta-analysis

72Citations
Citations of this article
142Readers
Mendeley users who have this article in their library.

Abstract

INTRODUCTION: Flash glucose monitoring (FGM) is a factory-calibrated sensor-based technology for the measurement of interstitial glucose. We performed a systematic review and meta-analysis to assess its efficacy and safety in patients with type 1 and type 2 diabetes. RESEARCH DESIGN AND METHODS: PubMed, CENTRAL, Scopus and Web of Science were searched in July 2019. Twelve studies with a follow-up longer than 8 weeks, evaluating 2173 patients on prandial insulin, multiple daily insulin injections or continuous subcutaneous insulin infusion were included. The following data were extracted: HbA1c, time in range, time above 180 mg/dL, time below 70 mg/dL, frequency of hypoglycemic events, number of self-monitoring of blood glucose (SMBG) measurements, total daily insulin dose, patient-reported outcomes, adverse events, and discontinuation rate. A comparison with SMBG was conducted. RESULTS: FGM use was associated with a reduction in HbA1c (-0.26% (-3 mmol/mol); p=0.002) from baseline to the last available follow-up, which correlated with HbA1c levels at baseline (-0.4% (-4 mmol/mol) for each 1.0% (11 mmol/mol) of HbA1c above 7.2% (55 mmol/mol)). Also, a decrease in time below 70 mg/dL was found (-0.60 hours/day; p=0.04). Favorable findings in patient-reported outcomes and no device-related serious adverse events were reported. When compared with SMBG, FGM was characterized by no statistically different change in HbA1c (p=0.09), with lower number of SMBG measurements per day (-3.76 n/day; p<0.001) and risk of discontinuation (relative risk=0.42; p=0.001). A limited number of studies, with a heterogeneous design and usually with a short-term follow-up and without specific training, were found. CONCLUSIONS: The present review provides evidence for the use of FGM as an effective strategy for the management of diabetes.

Cite

CITATION STYLE

APA

Castellana, M., Parisi, C., Di Molfetta, S., Di Gioia, L., Natalicchio, A., Perrini, S., … Giorgino, F. (2020). Efficacy and safety of flash glucose monitoring in patients with type 1 and type 2 diabetes: a systematic review and meta-analysis. BMJ Open Diabetes Research & Care, 8(1). https://doi.org/10.1136/bmjdrc-2019-001092

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free