Abstract
Purpose: The purpose of the present study was to assess the validity of a simple instrument for screening dysphagia used in a large public hospital in Brazil with heterogeneous adult population. Method: The Dysphagia Risk Evaluation Protocol (DREP) - screening version contains four items (altered cervical auscultation, altered vocal quality, coughing and choking before / during / after swallowing) that were previously indicated as independent risk factors associated to the presence of dysphagia in the swallowing test with water. Trained speech therapists administered and scored DREP – screening version to consecutive patients referred by hospital's medical team to perform Video Fluoroscopic for Swallowing Study (VFSS). Results: 211 patients received the swallowing screen (DREP): 99 failed and 112 passed. One in every five patients was randomized to receive a VFSS. The DREP screening version demonstrated excellent validity with sensitivity at 92.9%, specificity at 75.0%, negative predictive values at 95.5% and an accuracy of 80.9%. Conclusion: The DREP - screening version is a simple and accurate tool to identify the risk for penetration and / or aspiration in patients who are not tube-fed, who have a good level of alertness, have no history of recurrent pneumonia, are not on pneumonia, and that do not use a tracheostomy cannula.
Author supplied keywords
Cite
CITATION STYLE
de Lima, M. S., Sassi, F. C., de Medeiros, G. C., Jayanthi, S. K., & de Andrade, C. R. F. (2020). Diagnostic precision for bronchopulmonary aspiration in a heterogeneous population. CODAS, 32(5), 1–7. https://doi.org/10.1590/2317-1782/20202019166