Validation and comparison of EQ-5D-5L and SF-6Dv1 in myopic patients requiring corneal refractive surgery in China

0Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: Different health-related quality of life scales are suitable for various populations and scenarios; hence, the selection of measurement tools must be based on research objectives and focal points. To facilitate the choice between EQ-5D-5L and SF-6Dv1 in clinical and economic research of myopic patients undergoing corneal refractive surgery, the study aims to assess and compare EQ-5D-5L and SF-6Dv1 among the patients in China. Methods: A total of 411 participants with a mean age of 25.6 years were recruited. Information collected including demographic characteristics, EQ-5D-5L and SF-6Dv1. The ceiling effect was evaluated by calculating the proportion of participants who reported the best possible health states. Agreement between EQ-5D-5L and SF-6Dv1 health utility scores (HUSs) was tested using intraclass correlation coefficient (ICC) and Bland-Altman plot. Convergent validity of EQ-5D-5L and SF-6Dv1 HUSs was evaluated using the Spearman correlation coefficient (r) with VF-14 as a calibration standard. Results: Ceiling effects were 75.2% and 40.4% for EQ-5D-5L and SF-6Dv1, respectively. ICC between the two HUSs was 0.611 (average-measure). Bland-Altman plots showed that the agreement varied across different HUS segments. Correlation between EQ-5D-5L HUS and VF-14 (r = 0.363) was higher than that between SF-6Dv1 HUS and VF-14 (r = 0.226). EQ-5D-5L and SF-6Dv1 HUSs can only distinguish one clinical condition (i.e., chronic pain symptom); but they can identify health differences across all self-reported known-groups. EQ-5D-5L HUS had greater sensitivity; but SF-6Dv1 HUS was more responsive at follow-ups. Conclusions: EQ-5D-5L and SF-6Dv1 HUS cannot be used interchangeably in myopic patients undergoing corneal refractive surgery. It appears that EQ-5D-5L HUS performs better in terms of convergent validity and sensitivity; but SF-6Dv1 HUS is more responsive.

Cite

CITATION STYLE

APA

Liang, G., Zhang, A. X., Li, F. Y., Liu, J. H., Zheng, Y. J., Qin, Y., … Wang, P. (2025). Validation and comparison of EQ-5D-5L and SF-6Dv1 in myopic patients requiring corneal refractive surgery in China. Health and Quality of Life Outcomes, 23(1). https://doi.org/10.1186/s12955-025-02411-w

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free