Multiplex detection of three select agents directly from blood by use of the GeneXpert system

9Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Francisella tularensis, Bacillus anthracis, and Yersinia pestis are tier 1 select agents with the potential to rapidly cause severe disease. Rapid detection of these bacteria from patient samples at the point of care could contribute to improved clinical outcomes in the event of a bioterrorism attack. A multiplex nested PCR assay for detection of F. tularensis, B. anthracis, and Y. pestis directly from patient blood samples was developed using the GeneXpert system. The multiplex Gene- Xpert cartridge-based assay includes all necessary sample processing and amplification reagents. Blood samples spiked with different numbers of CFU were used to measure the analytical limit of detection (LOD) and dynamic range. Sensitivity was determined by testing spiked blood samples and negative-control blood in a blind manner. Specificity was determined by testing against nontarget pathogens and blood samples from clinical patients. The assay LOD was 8.5 CFU/ml for F. tularensis, 10 CFU/ml for B. anthracis, and 4.5 CFU/ml for Y. pestis. The sensitivity was 100% at the LOD for all three select agent bacteria in spiked patient blood samples. The assay specificity was 100% when it was tested against both nontarget pathogens and clinical patient blood samples. The total assay time was approximately 100 min. This automated assay, which is suitable for use at the point of care, identifies three select agents directly in blood without the need for enrichment with a high sensitivity within 100 min. This assay may enable rapid detection and treatment of patients infected with the target organisms in the event of a bioterrorism attack.

References Powered by Scopus

The MIQE guidelines: Minimum information for publication of quantitative real-time PCR experiments

12350Citations
N/AReaders
Get full text

Mfold web server for nucleic acid folding and hybridization prediction

11234Citations
N/AReaders
Get full text

Anthrax as a biological weapon, 2002: Updated recommendations for management

923Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Yersinia pestis: The natural history of Plague

121Citations
N/AReaders
Get full text

Deliberate release: Plague – A review

23Citations
N/AReaders
Get full text

Development and evaluation of a multiplex droplet digital polymerase chain reaction method for simultaneous detection of five biothreat pathogens

16Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Banada, P. P., Deshpande, S., Banik, S., Shah, D., Koshy, R., Patel, B., … Alland, D. (2019). Multiplex detection of three select agents directly from blood by use of the GeneXpert system. Journal of Clinical Microbiology, 57(5). https://doi.org/10.1128/JCM.00036-19

Readers over time

‘19‘20‘21‘23‘2402468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 7

78%

Researcher 2

22%

Readers' Discipline

Tooltip

Biochemistry, Genetics and Molecular Bi... 3

33%

Immunology and Microbiology 3

33%

Agricultural and Biological Sciences 2

22%

Chemistry 1

11%

Save time finding and organizing research with Mendeley

Sign up for free
0