Rapid ablation for atrial flutter by targeting maximum voltage - Factors associated with short ablation times

22Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

Your institution provides access to this article.

Abstract

Background: The maximum voltage-guided (MVG) approach to ablation for atrial flutter targets high-amplitude signals along the cavotricuspid isthmus (CTI). It is based on the observation that the isthmus is often composed of bundles of conducting tissue and the hypothesis that these bundles manifest as high-amplitude electrograms, providing targets for selective ablation. We aim to identify patient and procedural factors that correlate with rapid isthmus ablation. Methods: All patients undergoing CTI ablation at our center from January 2005 to May 2006 were included. Patients were divided into outcome groups relative to the median value for total ablation time. The two groups were compared according to patient and procedural variables, using multivariate regression methods. Results: Seventy-six patients were assessed with mean age 60.2 ± 10.6 years; 63 (82.9%) were male. Mean ablation time to bidirectional block across the CTI was 6.85 ± 5.87 min (range 0.68-28.7); median 4.77 min. Seventy-six percent of patients required less than 5 min total ablation time until bidirectional block was achieved. Variables independently associated with a short ablation time were the presence of sinus rhythm at start of ablation (P = 0.0050, odds ratio (OR) 8.03), high mean temperature among all ablations (P = 0.019, OR 17.81), and low variability of mean power among all ablations (P = 0.0048, OR 19.26). Conclusions: Using the MVG approach to atrial flutter ablation, shorter total ablation times are observed among patients in sinus rhythm at the onset of ablation, with higher mean temperature among ablation lesions, and less variability of power between ablations. © 2007 by Futura Publishing Company, Inc.

Cite

CITATION STYLE

APA

Subbiah, R. N., Gula, L. J., Krahn, A. D., Posan, E., Yee, R., Klein, G. J., & Skanes, A. C. (2007). Rapid ablation for atrial flutter by targeting maximum voltage - Factors associated with short ablation times. Journal of Cardiovascular Electrophysiology, 18(6), 612–616. https://doi.org/10.1111/j.1540-8167.2007.00804.x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free