Abstract
Introduction: Central venous access devices are widely used in hospital practice. Complications associated with their use are well described and reviewed. In this paper, we report a former complication that in turn created a new complication during a standardized procedure. Case Presentation: We report the case of an 81-year-old Caucasian woman requiring total parenteral nutrition due to a high-debt enterocutaneous fistula. In a previous right subclavian catheterization a fragmentation of the tip of the catheter, probably not recognized at the time, provoked an extrinsic compression of the vessel. Conclusion: Fragmentation of a central venous catheter is a possible complication of catheterization and can be missed. Control of a catheter is imperative after its removal, even if not always practiced.
Cite
CITATION STYLE
Sidiropoulou, Z., João, P., Vasconcelos, P., & Couceiro, C. (2010). Right subclavian vein catheterism complication due to a “foreign body”: a case report. Journal of Medical Case Reports, 4(1). https://doi.org/10.1186/1752-1947-4-327