Cooling Capacity Test for MIL-101(Cr)/CaCl2 for Adsorption Refrigeration System

13Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

An MIL-101(Cr) powder material was successfully prepared using the hydrothermal synthesis method, and then the original MIL-101(Cr) was combined with different mass fractions of CaCl2 using the immersion method to obtain a MIL-101(Cr)/CaCl2 composite material. The physical properties of the adsorbent were determined by X-ray powder diffraction (XRD), an N2 adsorption desorption isotherm test, and thermogravimetric analysis (TG). The water vapor adsorption performance of the metal-organic frameworks MOFs was tested with a gravimetric water vapor adsorption instrument to analyze its water vapor adsorption mechanism. Based on the SIMULINK platform in the MATLAB software, a simulation model of the coefficient of performance (COP) and cooling capacity of the adsorption refrigeration system was established, and the variation trends of the COP and cooling capacity of the adsorption refrigeration system under different evaporation/condensation/adsorption/desorption temperatures was theoretically studied. MIL101-(Cr)/CaCl2-20% was selected as the adsorption material in the adsorption refrigeration system through the physical characterization of composite materials with different CaCl2 concentrations by means of adsorption water vapor test experiments. A closed adsorption system performance test device was built based on the liquid level method. The cooling power per unit and adsorbent mass (COP and SCP) of the system were tested at different evaporation temperatures (288 K/293 K/298 K); the adsorption temperature was 298 K, the condensation temperature was 308 K, and the desorption temperature was 353 K. The experimental results showed that COP and SCP increased with the increase in the evaporation temperature. When the evaporation temperature was 298 K, the level of COP was 0.172, and the level of SCP was 136.9 W/kg. The COP and SCP of the system were tested at different adsorption temperatures (293 K/298 K/303 K); the evaporation temperature was 288 K, the condensation temperature was 308 K, and the desorption temperature was 353 K. The experimental results showed that the levels of COP and SCP decreased with the increase in the adsorption temperature. When the adsorption temperature was 293 K, the level of COP was 0.18, and the level of SCP was 142.4 W/kg.

Cite

CITATION STYLE

APA

Liu, Z., Zhao, B., Huang, Y., Qi, X., & Lou, F. (2020). Cooling Capacity Test for MIL-101(Cr)/CaCl2 for Adsorption Refrigeration System. Molecules, 25(17). https://doi.org/10.3390/molecules25173975

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free