A high-efficiency coupling method using the gradient-index (GRIN) fiber probe and hollow-core photonic crystal fiber (HC-PCF) is proposed to improve the response time and the sensitivity of gas sensors. A coupling efficiency model of the GRIN fiber probe coupled with HC-PCF is analyzed. An optimization method is proposed to guide the design of the probe and five samples of the GRIN fiber probe with different performances are designed, fabricated, and measured. Next, a coupling efficiency experimental system is established. The coupling effciencies of the probes and single-mode fiber (SMF) are measured and compared. The experimental results corrected by image processing show that the GRIN fiber probe can achieve a coupling effciency of 80.22% at distances up to 180 μm, which is obviously superior to the value of 33.45% of SMF at the same distance. Moreover, with the increase of the coupling distance, the coupling efficiency of the probe is still higher than that of SMF.
CITATION STYLE
Wang, C., Zhang, Y., Sun, J., Li, J., Luan, X., & Asundi, A. (2019). High-efficiency coupling method of the gradient-index fiber probe and hollow-core photonic crystal fiber. Applied Sciences (Switzerland), 9(10). https://doi.org/10.3390/app9102073
Mendeley helps you to discover research relevant for your work.