Investigation of Pump Compatibility of Fast-Acting Insulin Aspart in Subjects With Type 1 Diabetes

49Citations
Citations of this article
61Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Ultra-fast-acting insulins, such as fast-acting insulin aspart (faster aspart), have pharmacokinetic properties that may be advantageous for patients using continuous subcutaneous insulin infusion (CSII), provided that they are compatible with and safe to use in CSII. Methods: Randomized, double-blind, parallel-group, actively controlled trial evaluating compatibility, efficacy, and safety of faster aspart in adults with type 1 diabetes using their own MiniMed Paradigm pump with Quick-Set or Silhouette infusion sets. Following run-in, subjects were randomized (2:1) to faster aspart (n = 25) or insulin aspart (n = 12) for 6 weeks. Primary endpoint was the number of microscopically confirmed episodes of infusion-set occlusions. Results: No microscopically confirmed episodes of infusion-set occlusions were observed in either arm. Seven possible infusion-set occlusions were reported by five subjects (all faster aspart); none were prompted by a plug observed by the subject (prompted by unexplained hyperglycemia [n = 6] or leakage [n = 1]) and none were confirmed. Macroscopic and microscopic evaluation showed no color change or particle/crystal formation in the infusion sets. Premature infusion-set changes were reported in 44% and 16.7% of subjects in the faster aspart and insulin aspart groups, respectively. A nonsignificant trend toward better efficacy was observed with faster aspart (estimated treatment difference [ETD] [95% CI] in HbA1c change: –0.14% [–0.40, 0.11]). No new safety issues were found in either treatment group. Conclusions: Over 6 weeks of treatment, no microscopically confirmed infusion-set occlusions were observed for faster aspart or insulin aspart, indicating similar compatibility with CSII use.

Cite

CITATION STYLE

APA

Zijlstra, E., Demissie, M., Graungaard, T., Heise, T., Nosek, L., & Bode, B. (2018). Investigation of Pump Compatibility of Fast-Acting Insulin Aspart in Subjects With Type 1 Diabetes. Journal of Diabetes Science and Technology, 12(1), 145–151. https://doi.org/10.1177/1932296817730375

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free