Analysis of optimal injection ratio of vapor injection heat pump for electric railway vehicles

7Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.

Abstract

Air-source heat pump with vapour injection is a prospective efficient heating method for electric railway vehicles in cold regions. A heating performance analysis modelling for air source heat pump with vapour injection is set up for performance optimization in this paper. The maximum errors of the program are within 15%. Heating performance, as well as the optimal injection ratio is analysed. The optimal injection ratio varies mainly from 0.12 to 0.3 under the typical working condition of railway vehicles in winter. It goes up with increasing inlet air temperature of condenser and goes down with increasing ambient temperature. The ambient temperature has very little effect on the optimal injection temperature of the internal heat exchanger. The results indicate that the

Cite

CITATION STYLE

APA

Zou, H., Han, X., Huang, G., Chen, Y., & Tian, C. (2019). Analysis of optimal injection ratio of vapor injection heat pump for electric railway vehicles. Journal of Sustainable Development of Energy, Water and Environment Systems, 7(4), 656–666. https://doi.org/10.13044/j.sdewes.d7.0280