Communication—Proving the Importance of Pt-Interlayer Position in PEMWE Membranes for the Effective Reduction of the Anodic Hydrogen Content

  • Martin A
  • Abbas D
  • Trinke P
  • et al.
21Citations
Citations of this article
41Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Gas crossover through the membrane poses a significant challenge to proton exchange membrane water electrolysers. This work investigates the influence of the position of platinum-based recombination interlayers integrated in the membrane on the anodic hydrogen in oxygen content. The results show that all interlayer positions reduce the anodic hydrogen content without performance losses compared to the reference without interlayer. However, an interlayer positioned closer to the anode is more effective than closer to the cathode. Further, the effect of the interlayer is more pronounced with increasing anode pressure.

Cite

CITATION STYLE

APA

Martin, A., Abbas, D., Trinke, P., Böhm, T., Bierling, M., Bensmann, B., … Hanke-Rauschenbach, R. (2021). Communication—Proving the Importance of Pt-Interlayer Position in PEMWE Membranes for the Effective Reduction of the Anodic Hydrogen Content. Journal of The Electrochemical Society, 168(9), 094509. https://doi.org/10.1149/1945-7111/ac275b