Background-Gadolinium (Gd)-based delayed-enhancement MRI (DEMRI) identifies nonviable myocardium but is nonspecific and may overestimate nonviable territory. Manganese (Mn2+)-enhanced MRI (MEMRI) denotes specific Mn2+ uptake into viable cardiomyocytes. We performed a dual-contrast myocardial assessment in a porcine ischemia-reperfusion (IR) model to test the hypothesis that combined DEMRI and MEMRI identifies viable infarct border zone (BZ) myocardium in vivo. Methods and Results-Sixty-minute left anterior descending coronary artery IR injury was induced in 13 adult swine. Twenty-one days post-IR, 3-T cardiac MRI was performed. MEMRI was obtained after injection of 0.7 mL/kg Mn2+ contrast agent. DEMRI was then acquired after injection of 0.2 mmol/kg Gd. Left ventricular (LV) mass, infarct, and function were analyzed. Subtraction of MEMRI defect from DEMRI signal identified injured BZ myocardium. Explanted hearts were analyzed by 2,3,5-triphenyltetrazolium chloride stain and tissue electron microscopy to compare infarct, BZ, and remote myocardium. Average LV ejection fraction was reduced (30±7%). MEMRI and DEMRI infarct volumes correlated with 2,3,5-triphenyltetrazolium chloride stain analysis (MEMRI, r=0.78; DEMRI, r=0.75; P<0.004). MEMRI infarct volume percentage was significantly lower than that of DEMRI (14±4% versus 23±4%; P<0.05). BZ MEMRI signal-to-noise ratio (SNR) was intermediate to remote and core infarct SNR (7.5±2.8 versus 13.2±3.4 and 2.9±1.6; P<0.0001), and DEMRI BZ SNR tended to be intermediate to remote and core infarct SNR (8.4±5.4 versus 3.3±0.6 and 14.3±6.6; P>0.05). Tissue electron microscopy analysis exhibited preserved cell structure in BZ cardiomyocytes despite transmural DEMRI enhancement. © 2011 American Heart Association, Inc.

Cite

CITATION STYLE

APA

Dash, R., Chung, J., Ikeno, F., Hahn-Windgassen, A., Matsuura, Y., Bennett, M. V., … Yang, P. C. (2011). Dual manganese-enhanced and delayed gadolinium-enhanced mri detects myocardial border zone injury in a pig ischemia-reperfusion model. Circulation: Cardiovascular Imaging, 4(5), 574–582. https://doi.org/10.1161/CIRCIMAGING.110.960591

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free