A novel two-element, catheter-based phased array coil was designed and built for both active MR device tracking and high-resolution vessel wall imaging. The device consists of two independent solenoid coils that are wound in opposite directions, connected to separate receive channels, and mounted collinearly on an angiographic catheter. The elements were used independently or together for tracking or imaging applications, respectively. The array's dual functionality was tested on a clinical 1.5 T MRI scanner in vitro, in vivo, and in situ. During real-time catheter tracking, each element gave rise to a high-amplitude peak in the respective projection data, which enabled reliable and robust device tracking as well as automated slice positioning. In vivo microimaging with 240 μm inplane resolution was achieved in 9 s using the device and TrueFISP imaging. Therefore, a single device was successfully implemented that met the combined requirements of intravascular device tracking and imaging. © 2004 Wiley-Liss, Inc.

References Powered by Scopus

The NMR phased array

1997Citations
N/AReaders
Get full text

Real‐time position monitoring of invasive devices using magnetic resonance

396Citations
N/AReaders
Get full text

On the heating of linear conductive structures as guide wires and catheters in interventional MRI

283Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Magnetic resonance - Compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: A review study

172Citations
N/AReaders
Get full text

MR-guided biopsy: A review of current techniques and applications

103Citations
N/AReaders
Get full text

Cardiovascular interventional magnetic resonance imaging

81Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Hillenbrand, C. M., Elgort, D. R., Wong, E. Y., Reykowski, A., Wacker, F. K., Lewin, J. S., & Duerk, J. L. (2004). Active Device Tracking and High-Resolution Intravascular MRI Using a Novel Catheter-Based, Opposed-Solenoid Phased Array Coil. Magnetic Resonance in Medicine, 51(4), 668–675. https://doi.org/10.1002/mrm.20050

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 26

62%

Researcher 9

21%

Professor / Associate Prof. 5

12%

Lecturer / Post doc 2

5%

Readers' Discipline

Tooltip

Engineering 26

58%

Medicine and Dentistry 11

24%

Physics and Astronomy 7

16%

Chemical Engineering 1

2%

Save time finding and organizing research with Mendeley

Sign up for free