Aortic root rupture during balloon-expandable transcatheter aortic valve replacement in a patient without recognized risk factors for aortic root rupture: A case report

6Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Aortic root rupture is a severe complication of balloon-expandable transcatheter aortic valve replacement (TAVR). Although previous studies have revealed several risk factors for this complication, predicting this complication is occasionally difficult. Case summary: A 78-year-old male patient underwent TAVR via a transfemoral approach using a 29-mm balloon-expandable valve. No recognized risk factors for aortic root rupture existed in pre-procedural multi-detector computed tomography (MDCT) analysis. However, after the valve deployment, sudden haemodynamic collapse occurred. Transoesophageal echocardiography revealed pericardial effusion, which led to an immediate diagnosis of cardiac tamponade following aortic root rupture. Following pericardial drainage via a subxiphoid approach, the haemodynamics were immediately stabilized. After 10 days of close observation, the patient was discharged on Day 39 without additional problems. He was still alive at the 6-month follow-up without sequelae. Discussion: Established risk factors for aortic root rupture include >20% area oversizing, bicuspid aortic valve, small annulus (<20 mm), shallow sinus of Valsalva (SOV) compared with the aortic annulus, and massive annular or subannular calcification. Our patient did not have any of the recognized risk factors for aortic root rupture, suggesting the existence of other factors. Pre-procedural MDCT showed a flat calcification orthogonal to the aortic root wall, and post-procedural MDCT revealed that this calcification penetrated the SOV with extravasation. Thus, we suggest that a flat calcification orthogonal to the aortic root wall might be an additional risk factor for aortic root rupture.

Cite

CITATION STYLE

APA

Tsuda, M., Mizote, I., Mukai, T., & Sakata, Y. (2020). Aortic root rupture during balloon-expandable transcatheter aortic valve replacement in a patient without recognized risk factors for aortic root rupture: A case report. European Heart Journal - Case Reports, 4(3). https://doi.org/10.1093/ehjcr/ytaa073

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free