PD04-05 AN ALGORITHMIC APPROACH TO IMPLEMENTATION OF A SINGLE-USE DIGITAL FLEXIBLE URETEROSCOPE RESULTS IN A DECREASE IN REUSABLE DIGITAL FLEXIBLE URETEROSCOPE REPAIR COSTS

  • Munver* R
  • Tsui J
  • Ahmed M
  • et al.
N/ACitations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

INTRODUCTION AND OBJECTIVES: Digital ureteroscopes offer enhanced optics compared to fiberoptic ureteroscopes, however they are also associated with increased repair costs. The selective use of a single-use digital flexible ureteroscope may preserve the life of reusable digital ureteroscopes and reduce the amount of costly repairs. We present our algorithmic approach to implementation of a single-use digital flexible ureteroscope (LithoVue®, Boston Scientific Corporation, Marlborough, MA) and evaluated the impact on scope repair costs. METHODS: An IRB approved retrospective review was performed of all digital flexible ureteroscopy procedures at our institution since January 2016. Our algorithm for using a single-use digital flexible ureteroscope was instituted in 2017, with indications: (1) large stone burden (> 1.5 cm), (2) multiple lower pole stones (> 3), (3) extensive laser use/expected operative duration (> 1 hour), (4) bilateral ureteroscopy, (5) stones within complex/tortuous renal anatomy, and (6) placement of ureteroscope through a trocar or nephroscope sheath. Perioperative data were analyzed, including number of procedures, repairs, and costs. RESULTS: The total number of ureteroscopy procedures was 418 [272 flexible (65%)] in 2016, 398 [318 flexible (80%)] in 2017, and 403 est. [308 flexible (76%)] in 2018. The total number of ureteroscope repairs was 47 (2016), 35 (2017), and 24 est. (2018). The cost savings was $88,683 (21% decrease) from 2016 to 2017, and $102,229 est. (30% decrease) from 2017 to 2018. The 2-year cost savings from 2016 to 2018 was $190,912 (44%). In 2017, a total of 63 single-use ureteroscopy procedures were performed for single/multiple indications: (1) 35, (2) 9, (3) 14, (4) 5, (5) 6, and (6) 6. In 2018 YTD, a total of 81 single-use ureteroscopy procedures were performed for the indications: (1) 49, (2) 19, (3) 3, (4) 5, (5) 6, and (6) 7. The single-use ureteroscope was used in additional procedures in 2017 (n=26) and 2018 (n = 10) to prevent surgery delay or cancellation when a reusable digital ureteroscope was not available, resulting in a positive contribution margin. CONCLUSIONS: Implementation of an algorithm for the LithoVue® resulted in a substantial decrease in reusable digital ureteroscope repair costs comparable to that in 2015, when fiberopic flexible ureterosocpy was exclusively performed at our institution. A single-use ureteroscope spares reusable ureteroscopes from excessive stress and damage, while potentially resulting in cost savings at high volume institutions.

Cite

CITATION STYLE

APA

Munver*, R., Tsui, J., Ahmed, M., Lovallo, G., Stifelman, M., & Degen, M. (2019). PD04-05 AN ALGORITHMIC APPROACH TO IMPLEMENTATION OF A SINGLE-USE DIGITAL FLEXIBLE URETEROSCOPE RESULTS IN A DECREASE IN REUSABLE DIGITAL FLEXIBLE URETEROSCOPE REPAIR COSTS. Journal of Urology, 201(Supplement 4). https://doi.org/10.1097/01.ju.0000555053.50974.40

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free