Abstract
The paper presents an overview of test results of 21 full-scale tests of wooden facades which were performed during an Austrian research project [1]. These tests were carried out according to ÖNORM B 3800-5 [2] and were the basis of Austrian classifications without further testing of the fire performance of wooden facades [3]. © Owned by the authors, published by EDP Sciences, 2013.
Cite
CITATION STYLE
APA
Teibinger, M., Matzinger, I., & Schober, P. (2013). Experimental study of the fire performance of wooden facades. In MATEC Web of Conferences (Vol. 9). EDP Sciences. https://doi.org/10.1051/matecconf/20130902004