The purpose of this study was to calculate and compare the plasma temperatures and electron densities from the laser-induced breakdown spectroscopy (LIBS) data collected by NASA's Martian rover and compare them to samples measured in Earth's atmosphere. Using the Boltzmann plots, LIBS plasma temperatures were obtained for each site. The analysis focused on titanium lines that were located in the spectral region between 300 and 310 nm. The electron density was measured using the Stark broadening of the hydrogen line at 656.6 nm; the full width at half maximum (FWHM) of this line can be measured and correlated to the electron density of the plasma. Due to a neighboring carbon peak with the hydrogen line seen in many of the spectra from the Martian sites, the FWHM needed to be calculated using a computer program that completed the other side of the hydrogen line and then it calculated the FWHM for those data samples affected by this. The plasma temperatures and electron densities of the Martian sites were compared to LIBS samples taken on Earth.
CITATION STYLE
Stetzler, J., Tang, S., & Chinni, R. C. (2020). Plasma temperature and electron density determination using laser-induced breakdown spectroscopy (LIBS) in earth’s and mars’s atmospheres. Atoms, 8(3). https://doi.org/10.3390/ATOMS8030050