Signal alteration of the cochlear perilymph on 3 different sequences after intratympanic GD-DTPA administration at 3 tesla: Comparison of 3D-FLAIR, 3d-T1-weighted imaging, and 3D-CISS

12Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

Abstract

Purpose: Three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) imaging after intratympanic gadolinium injection is useful for pathophysiologic and morphologic analysis of the inner ear. However, statistical analysis of diFFerences in inner ear signal intensity among 3D-FLAIR and other sequences has not been reported.We evaluated the signal intensity of cochlear fluid on each of 3D-FLAIR, 3D-T1-weighted imaging (T1WI), and 3D-constructive interference in the steady state (CISS) to clarify the diFFerences in contrast eFFect among these 3 sequences using intratympanic gadolinium injection. Methods: Twenty-one patients underwent 3D-FLAIR, 3D-T1WI, and 3D-CISS imaging at 3 tesla 24 hours after intratympanic injection of gadolinium. We determined regions of interest of the cochleae (C) and medulla oblongata (M) on each image, evaluated the signal intensity ratio between C and M (CM ratio), and determined the ratio of cochlear signal intensity of the injected side to that of the non-injected side (contrast value). Results: The CM ratio of the injected side (3.00±1.31, range, 0.53 to 4.88, on 3D-FLAIR; 0.83±0.30, range, 0.36 to 1.58 on 3D-T1WI) was significantly higher than that of the non-injected side (0.52±0.14, range, 0.30 to 0.76 on 3D-FLAIR; 0.49±0.11, range, 0.30 to 0.71 on 3D-T1WI) on 3D-FLAIR and 3D-T1WI (P<0.001), although no significant diFFerence was observed on 3D-CISS (10.03±2.19, range, 5.19 to 14.98, on the injected side; 9.52±1.63 range, 7.48 to 13.48, on the non-injected side) (P=0.11). The mean contrast value on 3D-FLAIR (5.93±2.57, range, 1.22 to 11.05) was significantly higher than that on 3D-T1WI (1.73±0.60, range, 0.98 to 3.09) (P<0.001). Conclusion: The 3D-FLAIR sequence is the most sensitive for observing alteration in inner ear fluid signal after intratympanic gadolinium injection. Our results warrant use of 3D-FLAIR as a sensitive imaging technique to clarify the pathological and morphological mechanisms of disorders of the inner ear.

Cite

CITATION STYLE

APA

Yamazaki, M., Naganawa, S., Kawai, H., Nihashi, T., & Nakashima, T. (2010). Signal alteration of the cochlear perilymph on 3 different sequences after intratympanic GD-DTPA administration at 3 tesla: Comparison of 3D-FLAIR, 3d-T1-weighted imaging, and 3D-CISS. Magnetic Resonance in Medical Sciences, 9(2), 65–71. https://doi.org/10.2463/mrms.9.65

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free