Thermoheliodome design, optimization and fabrication

3Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The Thermoheliodome, a digitally fabricated radiant cooling pavilion, addresses the energy challenge of buildings through a novel form and concept. We control the effective radiant temperature of a large area by expanding the surface area through reflection, which minimizes convective losses. Our novel geometric analysis for capture and concentration of diffuse heat emission from bodies resulted in a cone-shaped 'lamp' form. The optimization resulted in a hexagonal array of 55 cones across a 6 meter dome, which expands radiant emission surface area by a factor of 6, shifting outdoor comfort perception with minimal losses to the outside air.

Cite

CITATION STYLE

APA

Read, J. R., Meggers, F., Houchois, N., Aschwanden, G., Teitelbaum, E., Adriaenssens, S., … Pantelic, J. (2015). Thermoheliodome design, optimization and fabrication. In Energy Procedia (Vol. 78, pp. 273–278). Elsevier Ltd. https://doi.org/10.1016/j.egypro.2015.11.634