Abstract
This article deals with the implementation of the P-Class PMU compliant with IEC/IEEE Standard 60255-118-1:2018 by usage of a multiple-resonator (MR)-based approach for harmonic analysis having been proposed recently. In previously published articles, it has been shown that a trade-off between opposite requirements is possible by shifting a measurement time stamp along the filter window. Positioning the time stamp in a proximity of the time window center assures flat-top frequency responses. In this article, through simulation tests carried out under various conditions, it is shown that requirements of the IEC/IEEE Standard 60255-118-1:2018 can be satisfied by the second and third order MR structure for particular conditions of the time stamp location.
Author supplied keywords
Cite
CITATION STYLE
Kušljević, M. D., Tomić, J. J., & Poljak, P. D. (2021). On multiple-resonator-based implementation of iec/ieee standard p-class compliant pmus. Energies, 14(1). https://doi.org/10.3390/en14010198