Near-infrared temperature measurement technique for water surrounding an induction-heated small magnetic sphere

3Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

Abstract

A technique to measure the temperature of water and non-turbid aqueous media surrounding an induction-heated small magnetic sphere is presented. This technique utilizes wavelengths of 1150 and 1412 nm, at which the absorption coefficient of water is dependent on temperature. Water or a non-turbid aqueous gel containing a 2.0-mm- or 0.5-mm-diameter magnetic sphere is irradiated with 1150 nm or 1412 nm incident light, as selected using a narrow bandpass filter; additionally, two-dimensional absorbance images, which are the transverse projections of the absorption coefficient, are acquired via a near-infrared camera. When the three-dimensional distributions of temperature can be assumed to be spherically symmetric, they are estimated by applying inverse Abel transforms to the absorbance profiles. The temperatures were observed to consistently change according to time and the induction heating power.

Cite

CITATION STYLE

APA

Kakuta, N., Nishijima, K., Han, van C., Arakawa, Y., Kondo, K., & Yamada, Y. (2018). Near-infrared temperature measurement technique for water surrounding an induction-heated small magnetic sphere. Journal of Visualized Experiments, 2018(134). https://doi.org/10.3791/57407