A comparison of failure rates and canal preparation times between WaveOne Gold and One Curve file systems with and without glide path preparation in simulated canals

  • Pillay M
  • Vorster M
  • van der Vyver P
N/ACitations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

The aim of this study was to compare the failure rate and canal preparation times of the Primary WaveOne Gold file (Dentsply Sirona, Ballaigues, Switzerland) with the One Curve file (Micro Méga, Besançon, France). The influence of glide path preparation on failure rate and final preparation times were also evaluated. Endo training blocks (Dentsply Sirona) with simulated canals were separated into four groups: Group 1: Primary WaveOne Gold with WaveOne Gold Glider; Group 2: Primary WaveOne Gold without glide path; Group 3: One Curve with One G; Group 4: One Curve without glide path. The number of training blocks that were shaped before instrument fracture occurred was recorded. Glide path and final preparation times were also recorded. Where no glide path was prepared, One Curve file prepared a significantly higher number of canals (14.33± 0.58) than the Primary WaveOne Gold (4.6 ± 1.34) before instrument fracture occurred (p<0.001). The One Curve with One G Glide Path file prepared significantly higher number of simulated canals (28±1.41) than the Primary WaveOne Gold with WaveOne Gold Glider (15 ± 1.41) before instrument fracture (p<0.001). Glide path preparation times with WaveOne Gold Glider (4.8s) were significantly faster compared to the One G Glide Path file (7.29s)(p<0 .001). Significantly faster final canal preparation times were achieved in groups where glide path were prepared (p<0.001). One Curve files exhibits a greater fracture resistance than Primary WaveOne Gold files. Glide path preparation increases the longevity of preparation files and results in faster final canal preparation.

Cite

CITATION STYLE

APA

Pillay, M., Vorster, M., & van der Vyver, P. J. (2021). A comparison of failure rates and canal preparation times between WaveOne Gold and One Curve file systems with and without glide path preparation in simulated canals. South African Dental Journal, 76(5), 279–283. https://doi.org/10.17159/10.17159/2519-0105/2021/v76no5a6

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free