Medidas automatizadas de psicrômetro de termopar aspirado versus não aspirado

1Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

Abstract

The thermocouple is used for obtaining the air temperature with sensitivity and optimum precision, beyond great advantage over the mercury or alcohol thermometer, because it generates electrical signals that can be stored in automated systems. However, when it comes to obtaining the relative humidity from thermocouple, it is needed caution due to other factors involved. In this study two sets of thermocouple psychrometers, aspirated and no-aspirated were evaluated, relative to a Vaisala set, from 17 to 31/01/2008 (15 days). From measurements of dry and wet bulb temperatures, the relative humidity value was obtained, and it was possible to compare them with the Vaisala set measurements. The two types of psychrometers showed precision and accuracy in measurements of air temperature, and only precision in measurements of relative humidity, being that the aspirated psychrometer presented more precision. Despite the no-aspirated psychrometer has lesser precision in measurements, it is more robust because it is independent of a 12 VDC micro-fan, making it, a sensor with lesser risk of inadequate measures. Both aspirated and no-aspirated psychrometers do not measure accurately the relative air humidity during night period.

References Powered by Scopus

Construction and evaluation of an aspirated thermocouple psychrometer

17Citations
N/AReaders
Get full text

A low‐cost psychrometer for field measurements of atmospheric humidity

13Citations
N/AReaders
Get full text

Programming, connection and avaliation of a low cost aspirated thermocouple psychrometer in micrologger for agrometeorological studies

2Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Hourly reference evapotranspiration by Moretti-Jerszurki-Silva method using data from alternative station

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Da Cunha, A. R., & Volpe, C. A. (2014). Medidas automatizadas de psicrômetro de termopar aspirado versus não aspirado. Revista Brasileira de Meteorologia, 29(2), 271–280. https://doi.org/10.1590/S0102-77862014000200010

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

100%

Readers' Discipline

Tooltip

Engineering 4

67%

Agricultural and Biological Sciences 1

17%

Chemistry 1

17%

Save time finding and organizing research with Mendeley