Comparison of shear bond strength of metal orthodontic brackets bonded to a CAD/CAM prosthetic provisional material after the use of a self-adhesive resin cement versus a light adhesive paste and different surface conditioning protocols: An in vitro study

0Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Adult orthodontic treatment has been increasingly popular, and brackets may need to be bonded to provisional crowns, including CAD/CAM crowns. The use of self-adhesive resin cement or light adhesive paste have been suggested with different surface conditioning protocols to improve the adhesion to CAD/CAM PMMA provisional crowns. Objective To determine and compare the in vitro shear bond strength (SBS) of metal brackets bonded to a provisional prosthetic CAD/CAM material after the use of different adhesive cements and surface conditioning protocols. Materials and methods: One hundred twenty Telio® CAD specimens were manufactured in 12 groups (n = 10). Each specimen was bonded to a metal bracket and divided according to adhesive technique (3M™Transbond™ XT Light Cure Paste or 3M™RelyX™ U200) surface treatment (macroretentions) and the use of silane. Half of the specimens were thermocycled (5000 cycles, 5 °C/55 °C water baths). The SBS test was carried out using a shear bond strength tester, and the type of adhesive failure was determined by means of the adhesive remnant index. The data were analysed with the Mann–Whitney test (α = 0.05). Results: Statistically significant differences (P < 0.001) in SBS were found among the groups. The group with macroretentions, silane, and not thermocycled was the one that obtained the highest average value (17.31 ± 4.89 MPa). The lowest average value was the group without macroretentions, without silane, and thermocycled (3.4 ± 3.37 MPa). Conclusion: The shear bond strength of brackets to provisional prosthetic CAD/CAM materials depended on the type of adhesive, surface treatment, and aging by thermocycling.

Cite

CITATION STYLE

APA

Morales, K., Garces, G., Yagnam, S., Bustos, V., Belfus, J., & Rojas, V. (2022). Comparison of shear bond strength of metal orthodontic brackets bonded to a CAD/CAM prosthetic provisional material after the use of a self-adhesive resin cement versus a light adhesive paste and different surface conditioning protocols: An in vitro study. International Orthodontics, 20(3). https://doi.org/10.1016/j.ortho.2022.100661

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free