A microbiological evaluation of level of disinfection for flexible cystoscopes protected by disposable endosheaths

12Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Flexible cystoscopy is used in urological outpatient departments for diagnostic cystoscopy of bladder cancer and requires a high-level disinfection between each patient. The purpose of this study was to make a microbiological post disinfection efficacy assessment of flexible cystoscopes (FC) using disposable sterile endosheaths. Methods. One hundred endosheaths underwent a leak-test for barrier integrity after cystoscopy. Microbiological samples from these cystoscopies were obtained; after removal of the endosheath, and after cleaning the scope with a detergent cloth, rinsing with tap water followed by 70% ethanol disinfection and subsequent drying. The number of colony forming units (cfu) from the samples was counted after 72 hours and then divided in three categories, Clean FC (<5 cfu/sample), Critical FC (5-50 cfu/sample) and High-risk FC (>50 cfu/sample). The result was compared with data of 10 years continuous control sampling recorded in the Copenhagen Clean-Endoscope Quality Control Database (CCQCD) and analyzed with a Chi-square test for homogeneity. Results: All 100 endosheaths passed the leak-test. All samples showed a Clean FC and low means of cfu. A query to the CCQCD, showed that 99.8% (1264/1267) of all FC with a built-in work-channel reprocessed in a WD were clean before use. Conclusion: The reprocessing of FC using endosheaths, as preformed in this study, provides a patient-ready procedure. The results display a reprocessing procedure with low risk of pathogen transmission, high patient safety and a valid alternative to the recommended high-level disinfection procedure of FC. However, the general impression was that sheaths slightly reduced vision and resulted in some patient discomfort. © 2013 Jørgensen et al.; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Jørgensen, P. H., Slotsbjerg, T., Westh, H., Buitenhuis, V., & Hermann, G. G. (2013). A microbiological evaluation of level of disinfection for flexible cystoscopes protected by disposable endosheaths. BMC Urology, 13. https://doi.org/10.1186/1471-2490-13-46

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free