Abstract
In order to clarify the extraction behavior of U(VI) from aqueous phase to organic one in microchannel, we have carried out extraction experiments of U(VI) from HNO3 aqueous solution of 3 M (M = mol/dm3) to 30% or 100% TBP phase in microchannel. From the results of extraction experiments, it was found that the extraction of U(VI) in microchannel could be performed in a short time for approximately 1 s with a good extractability in both organic phases of 30% and 100% TBP, and suggested that the other nuclides could be extracted with high extraction efficiency in microchannel. Furthermore, it is expected that the innovative and sophisticated nuclide separation systems can be developed by using microchannel extraction with selective extractants for specific nuclide. © 2005 Published by Elsevier Ltd. All rights reserved.
Author supplied keywords
Cite
CITATION STYLE
Hotokezaka, H., Tokeshi, M., Harada, M., Kitamori, T., & Ikeda, Y. (2005). System for high-level radioactive waste using microchannel chip - Extraction behavior of metal ions from aqueous phase to organic phase in microchannel. In Progress in Nuclear Energy (Vol. 47, pp. 439–447). Elsevier Ltd. https://doi.org/10.1016/j.pnucene.2005.05.045