Abstract
Background: Free-breathing phase-resolved functional lung (PREFUL)-MRI may be useful for treatment monitoring in chronic obstructive pulmonary disease (COPD) patients with dyspnea. PREFUL test–retest reliability is essential for clinical application. Purpose: To measure the repeatability of PREFUL-MRI ventilation (V) and perfusion (Q) parameters. Study Type: Retrospective and prospective. Population: A total of 28 COPD patients and 57 healthy subjects. Field Strength/Sequence: 1.5T MRI/2D spoiled gradient echo imaging. Assessment: V and Q lung parameter maps based on three coronal slices were obtained at baseline and after 14 days (COPD patients) or after a short pause outside the scanner (healthy subjects). Regional ventilation (RVent) and imaging flow volume loops by cross-correlation (ccVent) were quantified. Q was normalized to the signal of the main pulmonary artery (QN) and quantified (QQuant). Pulmonary pulse wave transit time (pPTT), voxel-by-voxel (regional), and whole lung (global) ventilation defect percentage based on RVent (VDPRVent) and ccVent (VDPccVent), perfusion defect percentage (QDP), and ventilation/perfusion match based on RVent (VQMRVent) and ccVent (VQMccVent) were calculated. Statistical Tests: Regional V and Q were analyzed globally for each subject. Each parameter's median of scans 1 and 2 were assessed by Wilcoxon sign rank test. A parameter's repeatability was analyzed by Bland–Altman analyses, coefficients of variation, intraclass correlation coefficients (ICC), and power calculations. The regional voxel repeatability was examined by calculating the Sørensen–Dice coefficient. Results: There was no bias and no significant differences between the first and second MRI for any parameters (P > 0.05). Coefficient of variation ranged from 2.26% (ccVent) to 19.31% (QDP), ICC from 0.93 (QDP) to 0.60 (pPTT), the smallest detectable difference was 0.002 ccVent. Regional comparison showed the highest overlap (84%) in VDPRVent in healthy voxels and the lowest (53%) in VDPccVent defect voxels. Data Conclusion: V and Q PREFUL-MRI parameters were repeatable over two scan sessions in both healthy controls and COPD patients. Level of Evidence: 2. Technical Efficacy Stage: 2.
Author supplied keywords
Cite
CITATION STYLE
Pöhler, G. H., Klimeš, F., Behrendt, L., Voskrebenzev, A., Gonzalez, C. C., Wacker, F., … Vogel-Claussen, J. (2021). Repeatability of Phase-Resolved Functional Lung (PREFUL)-MRI Ventilation and Perfusion Parameters in Healthy Subjects and COPD Patients. Journal of Magnetic Resonance Imaging, 53(3), 915–927. https://doi.org/10.1002/jmri.27385
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.