The shunt active power filter to compensate reactive power and harmonics with optimized PI controller in a 3 phase 3 wire distribution network

0Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

In this paper is to study the denomination Power quality and large refers to maintaining a proximal sinusoidal power distribution bus voltage at rated magnitude and frequency. This is mainly affected by the generation of harmonics. Even though electronic and non-linear devices are flexible, economical and energy efficient, they may degrade power quality by creating harmonic currents and consuming excessive reactive power. A family of various shunt hybrid active power filters has been explored in shunt and series configurations to compensate for different types of nonlinear loads. They provide controlled current injection to remove harmonic current from the source side of electric system and also can improve the power factor. This paper shows the method of improving the power quality using shunt active power filter with proposed optimized PI. The proposed topic comprises of PI controller, filter hysteresis current control loop, dc link capacitor. The switching signal generation for filter is from hysteresis current controller techniques. With the all these element shunt active power filter reduce the total harmonic distortion. Its source current, compensating current and THD values are studied, then PI control strategy is applied then the differences in THD are compared. The PI feedback compensation design starts with the small signal system’s transfer function. Then an optimum constant of PI for a Shunt-APF is proposed and implemented to enhance its response to compensation of harmonics of linear and non-linear loads. The obtained results have demonstrated the ability to compensate the current harmonics effectively under distorted source conditions. The fluctuation in the dc bus voltage of the filter depends on the compensation speed of the outer loop that regulates the dc bus voltage. The proposed shunt active filter model uses balanced linear and non-linear load works successfully lowers the THD within IEEE norms and satisfactorily works to compensate current harmonics. The model is made in MATLAB / SIMULINK and successfully reduces the harmonic in the source current.

Cite

CITATION STYLE

APA

Managule, S. S., Dabhole, S., & Gupta, S. (2018). The shunt active power filter to compensate reactive power and harmonics with optimized PI controller in a 3 phase 3 wire distribution network. International Journal of Innovative Technology and Exploring Engineering, 7(4), 1–7. https://doi.org/10.31142/ijtsrd18196

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free