Abstract
© The Author(s) 2017. In order to assess the durability of La0.6Sr0.4Co0.2Fe0.8O3 oxygen electrodes in reversible solid oxide cells, current switched ~1000 h galvanostatic (0.7, 1.0, and 1.5 A/cm2) life tests were performed on symmetrical Ce0.9Gd0.1O2-electrolyte cells at 700°C. Cell operating voltage and resistance, the latter measured by impedance spectroscopy, were monitored throughout. Degradation was minimal for the 0.7 A/cm2 case. For the higher current densities, the cell voltage and resistance increased with time, although the cell appeared to stabilize after ~500 h in the 1.5 A/cm2 case. Post-test analyses showed no evidence of electrolyte cracking or delamination for any current. However, 3D imaging revealed measureable microstructural coarsening after 1.5 A/cm2 operation that was not present after 0.7 A/cm2 operation. Furthermore, the amount of Sr segregated onto LSCF surfaces was higher for the cells operated with current switching versus the as-prepared and zero-current cells. Analysis of the results suggest that much of the degradation was due to decreased oxygen surface exchange rate due to current-enhanced Sr segregation, with a smaller contribution due to microstructural coarsening. The possibility of extrapolating these accelerated tests to longer times is discussed.
Cite
CITATION STYLE
Railsback, J. G., Wang, H., Liu, Q., Lu, M. Y., & Barnett, S. A. (2017). Degradation of La 0.6 Sr 0.4 Fe 0.8 Co 0.2 O 3-δ Oxygen Electrodes on Ce 0.9 Gd 0.1 O 2-δ Electrolytes during Reversing Current Operation. Journal of The Electrochemical Society, 164(10), F3083–F3090. https://doi.org/10.1149/2.0111710jes
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.